Release Notes EdasWin ------------------------------------------ 17.34 6.11.2025 ------------------------------------------- New Signals in the analysis window can now be color-coded to match a measurement file. New Bookmarks now use the signal color for the bookmark text. New Bookmarks use the creation index per channel for the background color. For example: The first bookmark in signal s0 is yellow, the second bookmark is then blue, and so on. New If signal color is selected based on file index, the filename in the channel report window and the file selection window is colored accordingly. --------------------------------------- 17.32 9.10.2025 ------------------------------------------- New The TMark() function in the table now outputs bookmarks. Fixed Selecting multiple rows in the analysis procedure and then running the function on the analysis computer only overwrites the first bookmark. ------------------------------------------ 17.31 24.09.2025 ------------------------------------------- New For export from "efs" files into "mf4" files a timerange is definable. ------------------------------------------ 17.3 September 11, 2025 ------------------------------------------- New Extension of the supp() function on the analysis calculator. Signal jumps can now be corrected automatically. ------------------------------------------ 17.29 September 9, 2025 ------------------------------------------- New Export of an efs file to an MF4 file can now also be linked to ARXML ------------------------------------------ 17:28 09/03/2025 ------------------------------------------- Fixed Overlaying channels shift the chart position to the right, even if all overlaying channels have the same Y axis label. ------------------------------------------ 17:27 08/13/2025 ------------------------------------------- New Zoom copied to the results window if Y-selected channels are present, only those. In the order of selection. This also works without a selection frame. ------------------------------------------ 17.26 30.07.2025 ------------------------------------------- Fixed Display of analysis instructions shows a meaningless channel name behind the instruction for EFS files. ------------------------------------------ 17.25 16.06.2025 ------------------------------------------- New FlexRay frames with total content == 0 are ignored. New Signals from ARXML and FIBEX with names starting with ALIV_... and CRC_... are no longer offered for selection. New Signals from ARXML and FIBEX with undefined SlotID or CanId are no longer offered for selection. ------------------------------------------ 17.24 10.06.2025 ------------------------------------------- Fixed Sequential measurement with CANFD Box ?? When bus description files (FIBEX, ARXML, etc.) are used in EdasVX, ?? an error message is shown when loading the EFS file. ------------------------------------------ 17.23 17.04.2025 ------------------------------------------- New Display of alias for file names in the diagram. Fixed Input in the channel report search field was sometimes not too small. (Note This may be a typo or mistranslation; please clarify.) Fixed Changing files in the channel selection window resets the sorting. ------------------------------------------ 17.22 04.04.2025 ------------------------------------------- New New compiler version ------------------------------------------ 17.21 26.03.2025 ------------------------------------------- Fixed Channels that are grouped, overlaid, and displayed with the same Y-axis sometimes do not set the Y-axis to the same value. ------------------------------------------ 17.2 03/24/2025 ------------------------------------------- New Time range markers can be named. This name is then displayed in the header of the formatted table (F7) or included in the bookmarks. New Formatted table (F7) can now work with time ranges (between two cursors, selection frames, or time range markers). New Bookmarks can be automatically set to min, max, or average. Time ranges (between two cursors, selection frames, or time range markers) are also taken into account. ------------------------------------------ 17.12 03/20/2025 ------------------------------------------- Fixed Exporting to RPC3 with "Sort by Mnr" checked only sorts the data, not the Mnr and names. ------------------------------------------ 17.11 12.03.2025 ------------------------------------------- New Set cursor to Min. or Max. If a selection frame exists in the analysis window, you will be asked whether the Min/Max search should only be carried out within the selection frame. ------------------------------------------ 17.10 20.02.2025 ------------------------------------------- Fixed Change file name in channel selection or report Report view and only one file selecteddoesn't run since version 17.07. ------------------------------------------ 17.09 29.01.2025 ------------------------------------------- Fixed Grouping on top of each other and with the same Y-axis does not work if more channels are selected in the channel report view than channels are possible in the analysis window. Fixed Grouping on top of each other and with the same Y-axis does not work if the channels in the channel report view are clicked faster than they are displayed in the analysis window. ------------------------------------------ 17.08 28.01.2025 ------------------------------------------- New Marks in the channel report view can be saved and loaded. Fixed Regression line calculated incorrectly since version 17.07 ------------------------------------------ 17.07 January 20th, 2025 ------------------------------------------- New Regression now also shows the coefficient of determination. Fixed Dialog for manually sorting the file names only shows the file name. Fixed After returning from modify mode (analysis window is yellow), the wrong channels are highlighted in white in the analysis instructions window as currently visible. New Rename() function on analysis calculator renames signal. (Overwrites the data set name) New Display of the name from the data set is now the default in the analysis window instead of displaying the calculation. ------------------------------------------ 17.06 December 13th, 2024 ------------------------------------------- Fixed Display of the analysis instructions window can lead to a crash. ------------------------------------------ 17.05 11/29/2024 ------------------------------------------- New Scrolling in the analysis window scrolls lines in the analysis specification window if the lines belonging to the analysis window are no longer visible. ------------------------------------------ 17.04 10/30/2024 ------------------------------------------- Fixed Loading an "ewd" file that was saved with an "efs" file with an embedded bus description file results in an error message . ------------------------------------------ 17.03 10/30/2024 ------------------------------------------- New Replacing logical channel numbers with measuring point numbers or channel names does not work for signals from EFS files. ------------------------------------------ 17.02 28.10.2024 ------------------------------------------- Fixed If 2 channels are marked in the analysis window, depending on the last two channels in the analysis, these may not be calculated. (+-*/). ------------------------------------------ 17.01 22.10.2024 ------------------------------------------- New Replacing logical channel numbers with measuring point numbers or channel names in the analysis specification window. Fixed Double-clicking on FLX nodes in the channel selection window (bottom left) creates an additional file entry. ------------------------------------------ 17.00 9/28/2024 ------------------------------------------- New Support for EFS3 Files ----------------------------------------- 16.60 8/19/2024 ------------------------------------------- New Display of the nodes (buses) of an EFS file in the file selection window. The ARXML file is also assigned here if it was not defined in EdasVX for this node. ------------------------------------------ 16.50 8/19/2024 ------------------------------------------- Fixed Display of the EFS file with its nodes prevents the selection of files in the channel selection window. ------------------------------------------ 16.49 5.8.2024 ------------------------------------------- Fixed Signal ->Zoom in result window, set cursors, low-pass filter, move cursors, filter shows error message. ------------------------------------------ 16.48 1.8.2024 ------------------------------------------- Fixed Curve Function needs sometimes 2 attempts fpr propper function. Curve Function shifts the result sometime to the right side. ------------------------------------------ 16.47 30.7.2024 ------------------------------------------- Fixed Loading document with non existing data file results in anbormal termination. ------------------------------------------ 16.46 24.7.2024 ------------------------------------------- Fixed Right click in empty analysis window ends with abnormal termination. New Cursor info window for time diagramm reworked ------------------------------------------ 16.45 18.7.2024 ------------------------------------------- New Values in Cursor window are now right aligned. New User sort of file names in data file dialog is possible. Fixed Cursor in analysis window shows sometimes to few channels. ------------------------------------------ 16.44 17.6.2024 ------------------------------------------- New FadeIn FadeOut and FAdeBetween (Fdin,Fdout, Fdbw) functions on analysis calculator. New Changing file name in channel selection window (Multiselection) supports export in MDF4 Format ------------------------------------------ 16.43 6.6.2024 ------------------------------------------- Fixed Reading MF4 data file shows error message. " Rat. Polynom not supported" Fixed Display of imported unit "m/s²" shows special characters ------------------------------------------ 16.42 16.05.2024 ------------------------------------------- Fixed External videos (mpg,avi ...) can*t be shown. ------------------------------------------ 16.41 14.03.2024 ------------------------------------------- Fixed Textmarken im Analysefenster setzen mit markierten Kanälen und "Zeit" checkbox abgehakt zeigt Zeitline nicht an. ------------------------------------------ 16.40 27.02.2024 ------------------------------------------- Fixed Sometimes keywords in table for analysis window will not properly replaced. Fixed Analysis calculer and cursor dialog may be invisible if the main screen is on the right side. ------------------------------------------ 16.39 14.02.2024 ------------------------------------------- Neu Adjustable line width in analysis window for signals and axes/grid. ------------------------------------------ 16.38 31.01.2024 ------------------------------------------- Fixed Export in MF4 Format doesn't work properly if the clkrates of the channels are different. ------------------------------------------ 16.37 21.12.2023 ------------------------------------------- Fixed MF4 export from analysis window does not work properly if the channels have different clock rates. ------------------------------------------ 16.36 1.12.2023 ------------------------------------------- New Reference line (entering the Y position in the channel property) is now drawn in the channel color. This means that they can be assigned to the corresponding channel even when channels are placed one on top of the other. ------------------------------------------ 16.34 25.09.2023 ------------------------------------------- Fixed Export to RPC3 file with option "Sort by measuring point number" doesn't sort the scaling from the display. This means that measured values may be limited or too small for this RPC3 format. ------------------------------------------ 16.33 13.09.2023 ------------------------------------------- Fixed Export in EdasWin data format can rarely get stuck in an endless loop. EdasWin can then no longer be used. ------------------------------------------ 16.33 13.09.2023 ------------------------------------------- Fixed Change file (multiple selection...) does not take the file extension into account (e.g. .edt) This can lead to crashes or hangs. Fixed The option "Load document without calculating" makes no sense for Multiple selection of data files and export. The feature is temporarily switched off. ------------------------------------------ 16.32 22.08.2023 ------------------------------------------- Fixed Is channel reference in channel selection window (bottom left) set to Automatic, then no signals are displayed in the analysis window. New For edt measurement data with virtually defined CAN/CANFD and FlexRay channels the first undefined values are set to the first valid value. New When opening an efs file, the file dialog for the description file now also offers ".dbc" (CAN data base) files. ------------------------------------------ 16.31 10.08.2023 ------------------------------------------- Neu for efs measurement the first undefined value will be set to the first valid value. ------------------------------------------ 16.30 19.07.2023 ---- -------------------------------------- New Bookmark have more options. Fixed Common text mark for all channels is sometimes no longer visible after zooming. ------------------------------------------ 16.29 17.07.2023 ---- -------------------------------------- New Channel marking in the context menu of the analysis window. Function delete all, mark all channels of a file. New Channel reference (Mnr, name or logical channel number) is now extended by automatic. New Marking of the channel reference in the channel report view depending on the selected one Mode (Mnr, Name, logical channel number or Automatic) -------------------------------------------16.28 4.07.2023 ---- --------------------------------------- Fixed Cursor is no longer visible behind charts and other objects in the layout New selectable orientation of table in table function ------------------------------------------ 16.27 28.06.2023 ------------------------------------------- Neu Filekonverter efs->mf4 erzeugt für FlexRay eine um 1/3 kleinere Datei. ------------------------------------------ 16.26 28.06.2023 ------------------------------------------- Fixed Filekonverter efs->mf4 erzeugt bei Messung mit VXII Boxen um Faktor 100 zu große X-Achse. Wenn VX10 Boxen beteiligt sind. ist das Ergebniss in Ordnung. ------------------------------------------ 16.25 22.06.2023 ------------------------------------------- Fixed Fortschrittsanzeige während Anzeige von Kanälen aud efs Dateien können zu Fehlermeldungen wie "Eine unbennante Datei..." führen. ------------------------------------------ 16.24 20.06.2023 ------------------------------------------- Neu Erweiterte Fehlermeldungen bei Fileoperationen ------------------------------------------ 16.23 31.05.2023 ------------------------------------------- Fixed In seltenen Fällen kann die Funktion "Messdateien übertragen Block->Linear") zur Meldung "zu wenig Speicher" führen. (Hängt von Fragmentierung des Heap ab). ------------------------------------------ 16.22 23.05.2023 ------------------------------------------- Fixed Tabellenfunktionen geben immer Messstellennummern aus, statt der gewünschten Information. Neu Erweiterte Funktion für Beschriftungsmarken im Analysefenster Neu Cursor Setzen auf definierte Spanne Neu 20 und 24 point font in EdasWin. ------------------------------------------ 16.21 17.05.2023 ------------------------------------------- Fixed Linearisierungsfunktion fehlerhaft seit Compiler wechsel July 2022 Fixed Sometimes the cursor window flickers. New Same Y-axis for selected channels. New Selections dialog for channel mark show the filename, if data from more than one file are involved. New Für übereinandergelegte Kanäle mit gleicher Y-Achse wird nur noch eine Skala gezeigt. Neu Diagram based marks ------------------------------------------ 16.19 24.04.2023 ------------------------------------------- Fixed Table (F7) formats wrong since Windows 10H2/11. Fixed Transferring measurement data from block format to linear format can cause various error messages turn up. Fixed Transfer of measurement data from block format to linear format The target directory becomes the file names added instead of used as path. ------------------------------------------ 16.18 14.04.2023 ------------------------------------------- New Decimal komma in numeric fields will translated to '.' ------------------------------------------ 16.17 30.03.2023 ------------------------------------------- Fixed Screen Scalierung > 100% in the display settings makes fonts of cursor window bigger than the window. The unit is no more readable. ------------------------------------------ 16.15 27.03.2023 ------------------------------------------- New Progressbar for mf4 Export. Fixed "Rewrite data in original data set" doesn't function properly depending on the datat type. ------------------------------------------ 16.14 6.03.2023 ------------------------------------------- Fixed Analysis calculator not visible if previously on 2nd screen and this screen is deconnected. Neu Conversion from degree in minutes*100000 changes unit. ------------------------------------------ 16.13 14.02.2023 ------------------------------------------- Fixed Display of Video from EdasVX can terminate the program.(After switching optimizing options). Fixed Export of analog data und video sequenz into wmv file terminates the progran in Windows 11. ------------------------------------------ 16.12 3.02.2023 ------------------------------------------- Fixed Mouse wheel and ctrl key shifts signal minimal after zooming if no selection frame is activ. ------------------------------------------ 16.11 29.11.2022 ------------------------------------------- New Width of cursor dialog window is now sizeable by mouse. New Cursor dialog as well as the cursor windows in the signal view are no longer transparent. Fixed Left click next to view channel with overlaid analysis channel shows in selection window confused signs next to name and unit. Fixed Sometimes cells in the cursor dialog table are not completely deleted. Fixed Cursor windows can overlap on overlaid channels and are unreadable. New Text in cursor windows is now in signal color for overlaid channels. New Export from analysis to MDF4 file. ------------------------------------------ 16.10 25.11.2022 ------------------------------------------- New Export of EFS (FlexRay + CAN/FD) to MDF4 file in connection with a FIBEX file. ------------------------------------------ 16.02 07.09.2022 ------------------------------------------- Fixed Report view and loading an ewd file can lead to a crash. Fixed Microsoft Defender reports a virus on some computers. Due to other compiler optimization is that fixed. ------------------------------------------ 16.01 07.09.2022 ------------------------------------------- Fixed The name of the analysis in the analysis selection window is not saved correctly. ------------------------------------------ 16.00 12.08.2022 ------------------------------------------- New Automation via multiple selection of the files can now also be integrated into the existing edt file export New Group icon in channel report window New Grouping now also offers the same scaling for the overlaid channels. New Define names for analysis ------------------------------------------ 15.92 14.07.2022 ------------------------------------------- Fixed Autopolarity function reacts to manualy engtered polaritytext. A complete recalculation doesn't invert this channel then properly. Fixed Overlay channels in analysis window and zoom. Generate a new analysis and go back to the first analysis. Edaswin hangs. Fixed Overlay channels in analysis window and zoom. Enter modify mode sometimes doesn#t show a signal. Fixed Overlay channels in analysis window and zoom. Leave modify mode. Sometimes EdasWin hangs. ------------------------------------------ 15.91 6.04.2022 ------------------------------------------- New Loading "efs" files without embedded FIBEX file call AssignFibex automaticaly. ------------------------------------------ 15.90 7.03.2022 ------------------------------------------- Fixed Reading ASCII files with many lines of data header can handle data wrong. ------------------------------------------ 15.89 10.02.2022 ------------------------------------------- New Analysis calculator with big buttons via setting menu. New Revised search in channel report view. New Export into RPC3 file with sorting for sensor location number. New Export into RPC3 file gives the number of the channel with different samplingrate. New Number of Y markers in the analysis window are displayed in the lower left corner of the window. Fixed Deleting the channels in the analysis window via the context menu until no channel remains, leave the cursor and the selection frame. Sometimes subsequent operations cause EdasWin to crash or hang. Fixed Pointless special characters in the channel unit that come from the FIBEX file are deleted. New The analysis rule is highlighted in color. The blue field on the left becomes the Navigation used in the analysis window. ------------------------------------------ 15.88 08.02.2022 ------------------------------------------- Neu After manual editing in the analysis script(doubleclicko0n line) the mark will be resetted. Neu Marks im Analyse script window will be removed if marks are set in analysis window. ------------------------------------------ 15.87 26.01.2022 ------------------------------------------- New Conversion from rad/s into 1/min and back. ------------------------------------------ 15.86 24.01.2022 ------------------------------------------- Fixed Cursor window on second screen is no more visisble after switching to one screen mode. ------------------------------------------ 15.85 7.12.2021 ------------------------------------------- Neu Convert komplete edt file to RPC3. ------------------------------------------ 15.84 9.11.2021 ------------------------------------------- New Bigger Icons for search in report view. New "Cut" function works now also with two cursors. New YSampling allows supression of X Channel for retransformation. ------------------------------------------ 15.83 20.10.2021 ------------------------------------------- New Leftclick on a line in analysis script window make this channel visible in the analysisview. New Searching in report view with search or filter view. New ; as row delimiter for ASCI export ------------------------------------------ 15.82 13.10.2021 ------------------------------------------- New Maps and GPS data are always calculated internally to minutes * 100000. Fixed Old maps calibrated in deg will not shown properly. ------------------------------------------ 15.81 12.10.2021 ------------------------------------------- Fixed Stackoverflow after expansion of datafile with up to 16000 channels. Fixed Display of channelname in referenced channels (eg. &0.1) in modify mode terminates program. ------------------------------------------ 15.80 30.09.2021 ------------------------------------------- Fixed Map displays sometimes nothing depending on data format and used hardware. ------------------------------------------ 15.79 07.09.2021 ------------------------------------------- New Show name of channel in behind a referenc (z.B. &s0.2) in Analysis script window Kommentar angezeigt. ------------------------------------------ 15.78 31.08.2021 ------------------------------------------- Fixed MF4 New data types. New MF4 Entrys without data are no more displayed in channel selection window Fixed MF4 Error in zipped data between two blocks (Error in MF4 Data files) ------------------------------------------ 15.77 26.08.2021 ------------------------------------------- New Calculate GPS data identified by sensor location number from minutes *100000 into degreem. ------------------------------------------ 15.76 6.08.2021 ------------------------------------------- New You can enter a clkrate for reading asynchrounous MF4 oder MDF data files. ------------------------------------------ 15.75 13.07.2021 ------------------------------------------- New Egalize offset while merging data files with offc function. New Convversion from m/s in km/h und km/h in m/s overwrites unit in channel automatic. Fixed Merging efs /FlexRay and CAN/FD) data) data files doesn't run after supporting 2 CANFD Boxes. ------------------------------------------ 15.74 13.07.2021 ------------------------------------------- Fixed Fibex file with CANFD node contains ']' as last character in comment. Error message is "Error5" Fixed Exporting in EdasWin Format with large amount of data and block format can freeze progress bar in Windows 10. Fixed Dialog for changes since last version will bve displayed centered on acticve display. ------------------------------------------ 15.73 30.06.2021 ------------------------------------------- Neu optimized cache für for reading efs files. ------------------------------------------ 15.72 29.06.2021 ------------------------------------------- Fixed Cursor with a minimum of 2 diagramms.Rightklick mouse on cursor line between the diagramms Select "min" in context menu. Abnormal termination in EdasWin. Fixed Sometines reading of "efs" files freezes the progress bar bottom right. ------------------------------------------ 15.71 13.04.2021 ------------------------------------------- New RPC3 Export Dialog for selection of ' ' oder '_' delimiter beetween sensor location number and channelname. Selection for channel name with or without polarity ------------------------------------------ 15.7 04.04.2021 ------------------------------------------- Fixed Generating of sinus or noise with more than 2E9 samples is not possible. New RPC3 Export with '_' instead ' ' as deliniter beetween sensor location number and channel name. ------------------------------------------ 15.61 08.12.2020 ------------------------------------------- Fixed Not enough space in analysis window for the Y-axis if the preceding diagramm has fewer overlaying channels ------------------------------------------ 15.6 07.12.2020 ------------------------------------------- New Vector functions ------------------------------------------ 15.52 02.12.2020 ------------------------------------------- Fixed Labels on cursor may run into channel selection window. Neu Show programmable reference line in time diagram in analysis window. Fixed Helpfiles EdasWin.pdf und EdasWin_e.pdf not korrekt loaded. ------------------------------------------ 15.51 25.11.2020 ------------------------------------------- Fixed There is not enough space for Y-axis ifmore than 4 channels are combined in analysis window. New Format 0.n in table means n signifikante digits. Example #mean(s0,0.5) ------------------------------------------ 15.50 19.11.2020 ------------------------------------------- Fixed XY-Plott user naming for channel and left click on channelname doesn_t transfer name to dialog. Fixed Reading ewd file shows "error in *.ewd file" ------------------------------------------ 15.49 14.10.2020 ------------------------------------------- Neu Position for Label on XY Plott kann be top right. Additional free user defined text line below xy plott is possible. ------------------------------------------ 15.49 14.10.2020 ------------------------------------------- Fixed MATLAB export doesn't function for new versions ------------------------------------------ 15.48 17.09.2020 ------------------------------------------- Fixed Dupl or referenz as last command in analysis window and delete of a preceding analysis window can cause an endless loop ------------------------------------------ 15.47 10.09.2020 ------------------------------------------- Fixed ASCII Import with "(null)" instead "0" in rowes triggers error message ------------------------------------------ 15.46 27.07.2020 ------------------------------------------- New FIBEX 4.12 is supported. ------------------------------------------ 15.45 06.06.2020 ------------------------------------------- Fixed Only the first 10000 values from a efs file will be shown. ------------------------------------------ 15.44 18.06.2020 ------------------------------------------- Fixed Reading MDF4 data causes abnormal program termination ------------------------------------------ 15.43 28.01.2020 ------------------------------------------- Fixed Videoexport no Gamma correction Fixed Videoexport depending on the resolution only a part of the picture will be exported. ------------------------------------------ 15.42 9.01.2020 ------------------------------------------- New Using video export with analog- and videos now uses the original fps setting from the source video ------------------------------------------ 15.41 2.10.2019 ------------------------------------------- Fixed Loading ewd file with map but missing map on media and then using cursor generates abnormal termination. ------------------------------------------ 15.4 29.09.2019 ------------------------------------------- Fixed Overwrite of clkrate FlexRay data files. (file with extension efs) ------------------------------------------ 15.33 19.07.2019 ------------------------------------------- Fixed Call of ewd file with assigned FIBEX file generates abnormal termination if the FIBEX file is no more existent. ------------------------------------------ 15.32 17.06.2019 ------------------------------------------- Fixed Video recorded with EdVidUSB shoes error message. Fixed Video recorded with EdVidUSB doesn't show on the windows position. ------------------------------------------ 15.31 15.03.2019 ------------------------------------------- Fixed Video resets existing cursor to 0 Fixed Video (evs) start width maximum size on screen Fixed Abnormal termination if Video (evs) to short and cursor at end of data New Video files with avi,mpg or wmv extension are recognized ------------------------------------------ 15.3 14.11.2018 ------------------------------------------- New Video Export for all camera resolutions ------------------------------------------ 15.2 31.10.2018 ------------------------------------------- New Support for FIBEX 4.1 ------------------------------------------ 15.1 17.09.2018 ------------------------------------------- New Supports encrypted efs data header ------------------------------------------ 15.00 20.5.2018 ------------------------------------------- New Supports USB3 Camera streams Fixed Ratio for video is always 43 ------------------------------------------ 14.92 7.2.2017 ------------------------------------------- Fixed New time axis from the synchronisations funktion sometimes generates to much values. ------------------------------------------ 14.91 22.12.2017 ------------------------------------------- Fixed Manual entered position in cursor window will o m ore accepted. ------------------------------------------ 14.9 12.10.2017 ------------------------------------------- New Function for synchronizing data with different or non linear x axis. ------------------------------------------ 14.8 1.6.2016 ------------------------------------------- New Regression can manage one x mark and more then 1 y mark. ------------------------------------------ 14.79 12.01.2016 ------------------------------------------- New Export in binary file can store a matching header file with "txt" extension ------------------------------------------ 14.78 11.01.2016 ------------------------------------------- Fixed Video window reflects aspect ratio of video during sizing Fixed Zoom in curs window (GPS) zooms from upper left point Fixed Deleting cursor in analysis window doesn't delete cursor in Curs window Fixed Missing GPS values in the beginning of a measurement will be filled with the first found valid value. ------------------------------------------ 14.77 16.12.2015 ------------------------------------------- New TEAC data set Longitude is not negative for longitude with W (West) präfix ------------------------------------------ 14.76 29.10.2015 ------------------------------------------- New Slow Motion videos can be displayed with keyword $VideoSlowMotion in data header ------------------------------------------ 14.75 12.10.2015 ------------------------------------------- New Cursor window near cursor line can be deactivated ------------------------------------------ 14.74 24.09.2015 ------------------------------------------- Fixed per function RPM counts sometimes wrong for 1 clock. ------------------------------------------ 14.73 28.07.2015 ------------------------------------------- Fixed Can't read old Edas (DOS) data files. ------------------------------------------ 14.72 01.07.2015 ------------------------------------------- Neu OpenStreetMap map generation with coordinates recognized with sensor location numbers. ------------------------------------------ 14.71 21.06.2015 ------------------------------------------- New Using OpenStreetMap for automatic generation of map from data set with GPS koordinates Fixed Reading *.rsp data set with errornous data header (missing keyword CHANNELS) Fixed Assigned DBC (for CAN Bus stream) file will not be stored in the dokument ------------------------------------------ 14.7 21.04.2015 ------------------------------------------- Fixed Shift function supports padding with zeros or last value ------------------------------------------ 14.61 10.03.2015 ------------------------------------------- Fixed Merging edt data files with corresponding FlexRay data files (.efs extension) generates error message "Debug1". ------------------------------------------ 14.60 19.02.2015 ------------------------------------------- Fixed Reading of ASCII data files If some channels are not named names/unit and data is not correct assigned. ------------------------------------------ 14.59 17.02.2015 ------------------------------------------- Fixed illegal measurement values will be appended on signales from efs date files ------------------------------------------ 14.58 28.01.2015 ------------------------------------------- Fixed Drift(..) with uncalculated but zoomed time range corrects wrong time range. ------------------------------------------ 14.57 6.11.2014 ------------------------------------------- Fixed Extrakt FlexRay Messages from EFS file writes message ID dezimal instead hex. ------------------------------------------ 14.56 30.10.2014 ------------------------------------------- Neu Directreader reads MDF 4.0 Files exportes TurboLab. ------------------------------------------ 14.55 29.10.2014 ------------------------------------------- Fixed EFS data file If faktor for calculation from FIBEX file is 0 the software assumes 1 as default. New Extract FlexRay Messages from EFS data file. ------------------------------------------ 14.54 29.10.2014 ------------------------------------------- Fixed EFS data file und FIBEX 3.1 Some channels are not read correctly. ------------------------------------------ 14.53 27.10.2014 ------------------------------------------- New Cursor(...) Function in text window can handel fraction digits now. ------------------------------------------ 14.52 18.09.2014 ------------------------------------------- New Access to contents of EFS files with self defined table in TXT file. ------------------------------------------ 14.51 17.09.2014 ------------------------------------------- Fixed Sometimes abnormal program termination after reading MDF4 files. ------------------------------------------ 14.5 12.09.2014 ------------------------------------------- New Direct reader for MDF4 data files. New Converter for MDF4 files. ------------------------------------------ 14.43 02.09.2014 ------------------------------------------- Neu change of file name in chanels selection windowat changes the corresponding FleyRay (*.efs) data file too. Fixed Transfer file from blöock to linear mode doesnt copy the corresponding FlexRay (*.efs) data file. ------------------------------------------ 14.42 08.08.2014 ------------------------------------------- New Max. number of channels increased to 4096 ------------------------------------------ 14.41 25.07.2014 ------------------------------------------- Fixed Channel report window doesn't show FLX Icon if FlexRay binary exists for edt data file. ------------------------------------------ 14.4 24.04.2014 ------------------------------------------- New Support of FlexRay binary files with extension 'efs' ------------------------------------------ 14.3 2.03.2014 ------------------------------------------- New Replace() Function on analysis calculator. Replaces Siganl without changing Name,MNR, log channels number etc. ------------------------------------------ 14.2 16.01.2014 ------------------------------------------- New Load and store color scheme in color dialog (Main menu -> settings -> colors) New Definable width and high for analysis window (Mainmenu -> View) ------------------------------------------ 14.13 13.01.2014 ------------------------------------------- Fixed rpm Mode in per() mode delivers same result as freq. Muliplikation with 60 is missing. ------------------------------------------ 14.13 18.12.2013-------------------------------------------- Fixed rpm node in per() delivers 0 as result. ------------------------------------------ 14.12 29.10.2013-------------------------------------------- Fixed small 'p' could not be entered in text windows. ------------------------------------------ 14.11 5.09.2013-------------------------------------------- Fixed ch10 sequential files will rarely not be merged properly. ------------------------------------------ 14.1 20.08.2013-------------------------------------------- Fixed lowpass filter runs as fixpoint since version 14.00 filter. This generates more noise. ------------------------------------------ 14.00 18.07.2013-------------------------------------------- New Filter funktions combined in "filter" button on analysis calculator ------------------------------------------ 13.01 15.07.2013-------------------------------------------- Fixed Merge of "edt" Files under the mainmenu writes zeros if the files are linear organised. ------------------------------------------ 13.00 10.07.2013-------------------------------------------- Fixed Grid lines in diagram of octave analysis may overlay the signal. ------------------------------------------ 12.99 08.07.2013-------------------------------------------- Fixed 16 Bit data in 32 bit data set will be read wrong. In this case all channels show strange values. This behavior is since Version 12.94 ------------------------------------------ 12.98 05.07.2013-------------------------------------------- Fixed Octave analysis doesn't show a result. ------------------------------------------ 12.97 02.07.2013-------------------------------------------- Fixed Spike suppression doesn't allow negative values as absolut level. ------------------------------------------ 12.96 24.05.2013-------------------------------------------- Neu Supports new synchronisation scheme for asynchronous video streams. ------------------------------------------ 12.95 26.04.2013-------------------------------------------- New For conversion from GPS coordinates in m it is possible to chose starting point a refernce (0m,0m). ------------------------------------------ 12.94 16.04.2013-------------------------------------------- Fixed RPC3 Import with length of channel name == 96 chars appends following keyword to the channel name Fixed Read to much channels from CH10 file cause "out of memory"c error. ------------------------------------------ 12.93 15.04.2013-------------------------------------------- Fixed ASCII Import adaption to FalCon high speed video system ------------------------------------------ 12.92 15.04.2013-------------------------------------------- Fixed Export into RPC3 and channel name with more than 96 characters writes invalid header ------------------------------------------ 12.91 09.03.2013-------------------------------------------- Fixed No more phase shift in per(...) function (was not wrong but confusing) ------------------------------------------ 12.90 08.03.2013-------------------------------------------- New Channel Frequency class Filters CHC60, CFC180, CFC600 and CFC1000 ------------------------------------------ 12.86 14.02.2013-------------------------------------------- Fixed Sound channel as first and onest channels will not be displayed. ------------------------------------------ 12.85 29.01.2013-------------------------------------------- Neu CTRL+Cursor left, CTRL+Cursor right changes the display rangein zoom mode (equivalenmt to CTRL+Mouse wheel) ------------------------------------------ 12.83 20.10.2012-------------------------------------------- New UFF58 Export can write an own file for every channel New UFF58 Export always in double format New Selectable stream number for export of video streams and analog data into a WMV, if more then one stream exists. ------------------------------------------ 12.82 04.10.2012-------------------------------------------- Fixed Pressing the "Repeat" button without prior calculation terminates abnormal for damage calculation. ------------------------------------------ 12.81 06.09.2012-------------------------------------------- Fixed Y-Sampling (new sampling) with 64 Bit floating point numbers as X-axis writes wrong data. ------------------------------------------ 12.80 28.08.2012-------------------------------------------- Fixed Old video sequences without white balance will be displayed to dark. ------------------------------------------ 12.79 24.07.2012-------------------------------------------- Fixed The X- and Y- axis of X/Y plot with more than 2 curves combined in one diagram can not be changed manualy. ------------------------------------------ 12.78 10.07.2012-------------------------------------------- New Automatic synchronization of videos captured with unsynchronized running cameras ------------------------------------------ 12.77 04.07.2012-------------------------------------------- New DATaRec4 CH10 with foreign annotation block can be read. Only voltage range will be shown. ------------------------------------------ 12.76 03.07.2012-------------------------------------------- New DATaRec4 annotation can be read from PC if none is in the ch10 file. ------------------------------------------ 12.75 20.06.2012-------------------------------------------- Fixed Cut function for data points and export into EdasWin format exports invalid values ------------------------------------------ 12.74 19.06.2012-------------------------------------------- Fixed Cut function for data points converts from 64 Bit into 32 Bit floating point ------------------------------------------ 12.73 19.06.2012-------------------------------------------- Fixed Insert function for data points converts from 64 Bit into 32 Bit floating point ------------------------------------------ 12.72 18.06.2012-------------------------------------------- Fixed Insert function for data points doesn't function with number of data points > 262140 ------------------------------------------ 12.71 23.05.2012-------------------------------------------- Fixed Concatenate of edt data files (in Export/Import of main menu) exports sometimes to few data points for the last channel. ------------------------------------------ 12.70 16.04.2012-------------------------------------------- Neu Insert datapoints from selection frame behind the first cursor position. ------------------------------------------ 12.68 13.03.2012-------------------------------------------- New Autoscaling for exporting WAV with diagram yhigh and ylow as highest level. ------------------------------------------ 12.67 9.03.2012-------------------------------------------- Fixed Merge of "edt" files generated with with foreign software packages can generate an abnormal termination. ------------------------------------------ 12.66 28.02.2012-------------------------------------------- New Read compressed herader from ch10. ------------------------------------------ 12.65 13.02.2012-------------------------------------------- New White balance from Videosteam is used. ------------------------------------------ 12.64 07.02.2012-------------------------------------------- New Export in EdasWin Format allows selection wether the analysis lines to be exported or not. ------------------------------------------ 12.63 26.01.2012-------------------------------------------- Fixed Concatenation of "edt" files that have been measured with several days between them, are sometimes concatenated in the wrong order. ------------------------------------------ 12.62 17.01.2012-------------------------------------------- Fixed CH10 Files CAN messages with 29 Bit CANid will not be recognized. ------------------------------------------ 12.61 11.01.2012-------------------------------------------- New EdasWin can play files (sound card) with 22050 and 44100 Hz sample frequency. ------------------------------------------ 12.6 9.01.2012-------------------------------------------- Neu EdasWin without Dongle can read and show all supported data formats. ------------------------------------------ 12.5 4.12.2012-------------------------------------------- New Support of CH10 files with CAN messages. ------------------------------------------ 12.45 2.12.2011-------------------------------------------- New Revision of 1/N Octav analysis ------------------------------------------ 12.44 25.10.2011-------------------------------------------- New F12 makes screen shot of EdasWin application and stores it in the folder \\EdasWin\Screen New Ctrl+F12 makes Screen shot from complete screen and stores it in the folder \\EdasWin\Screen ------------------------------------------ 12.42 12.10.2011-------------------------------------------- New Direct reader for wav files (PCM coded).Export into WAV file. ------------------------------------------ 12.41 05.10.2011-------------------------------------------- Fixed Table function leaves tmp.stk file in temporary stack. Fixed Drift function can't calculate the last data point of a dataser. ------------------------------------------ 12.40 28.09.2011-------------------------------------------- New Export of Video stream and analog data into a WMV (Windows Media Video) file. ------------------------------------------ 12.31 15.09.2011-------------------------------------------- New Dongle Remote Control. ------------------------------------------ 12.31 26.08.2011-------------------------------------------- Fixed Copy + Paste of layout window to WORD 2007 shows an ugly aspect ratio. ------------------------------------------ 12.3 25.08.2011-------------------------------------------- Neu Merge of .edt files beläßt leaves the original data types (int16, int32, float) and stores the destination file linear organised. ------------------------------------------ 12.22 15.06.2011-------------------------------------------- Fixed Language switch with Windows 7 doesn't function properly. ------------------------------------------ 12.21 07.06.2011-------------------------------------------- New Converter from Edas Video Stream (*.evs") to WMV under Export/Inmport menu. ------------------------------------------ 12.20 14.05.2011-------------------------------------------- Fixed Export data to EdasWin don't write unit for X-axis into data header. ------------------------------------------ 12.19 07.04.2011-------------------------------------------- Fixed Sensor location numbers in data header with leading blanks will not be recogniuzed. ------------------------------------------ 12.18 06.04.2011-------------------------------------------- New RPCIII direct reader can read different time and date formats. New RPCIII export writes time of start measurement in changed format. ------------------------------------------ 12.17 04.04.2011-------------------------------------------- New 32 Bit CH10 Files now supported. ------------------------------------------ 12.16 15.03.2011-------------------------------------------- Fixed Y-Axis marks in levelcrossing, Rangepair ... diagrams will not be displayed after window refresh. ------------------------------------------ 12.15 14.03.2011-------------------------------------------- New File name change in the channel selection window leads to non calculation if the option under settings to "load Doc.without calc." is selected ------------------------------------------ 12.14 11.03.2011-------------------------------------------- New RPC3 Export writes the date of measurement and not the date of conversion in the header of the RPC3 file. ------------------------------------------ 12.13 1.03.2011-------------------------------------------- New Rainflow bzw. Rangepair aus Rainflow erkennt Bereichsüberschreitung und fragt nach Weiterrechnen ------------------------------------------ 12.12 25.02.2011-------------------------------------------- New Mark dialog for overlayed channels allows delete of all marks. ------------------------------------------ 12.11 24.02.2011-------------------------------------------- New Simultaneous marking of overlayed signals is possible. ------------------------------------------ 12.1 22.02.2011-------------------------------------------- New Replace time marks ------------------------------------------ 12.06 14.11.2011-------------------------------------------- Neu Set maximum length of line buffer up to 32768 characters for ASCII Inmport ------------------------------------------ 12.05 10.12.2010-------------------------------------------- Fixed UFF58 Export crashes with big files. ------------------------------------------ 12.04 09.12.2010-------------------------------------------- New Rewrite processed signals back to the original dataset. ------------------------------------------ 12.03 07.12.2010-------------------------------------------- New Per() Function of Analysis calculator supports frequenz und RPM calculation. ------------------------------------------ 12.02 28.11.2010-------------------------------------------- New New window function (Low Sidelob) for FFT based analysis. Fixed UFF58 Export callc MATLAB Export. ------------------------------------------ 12.02 25.10.2010-------------------------------------------- Fixed Working with memory commands (sto und rcl) of the anqalysis calculator is not possible in the advanced (yellow background) mode. ------------------------------------------ 12.01 19.10.2010-------------------------------------------- New Marks in anqalysis window will be stored with the document New Break apart Auseinanderlegen von Übereinnaderliegenden Signalen funktioniert auch einzeln New Kursfenster wird mitgeladen wenn es beim Speichern anwesend war. New Fahrbahnranddarstellung farbig (linksgruen rechtsrot) ------------------------------------------ 12.00 29.09.2010-------------------------------------------- New Lane analysis with GPS coordinates. ------------------------------------------ 11.99 28.09.2010-------------------------------------------- New Invert the sequence of measurement points. Call via "conv" Menü in analysis calculator. ------------------------------------------ 11.98 15.08.2010-------------------------------------------- Neu Varianz, Skewness and Kurtosis functions for tables and analysis calculator. ------------------------------------------ 11.97 29.07.2010-------------------------------------------- New Power Spektrum additional to Power Spectal Density in analysis menu. New Cross Spektrum additional to Cross Spectal Density in analysis menu. ------------------------------------------ 11.96 27.07.2010-------------------------------------------- New If the Analysis calculator is shifted outside the desktop (e.g. switch screen resolution) it will be removed to the left upper corner on the desktop after the next start of EdasWin. ------------------------------------------ 11.95 28.05.2010-------------------------------------------- Fixed Can't read new ch10 files. ------------------------------------------ 11.94 12.05.2010-------------------------------------------- New Export in RPC3 Format adds the channel polarity to the channel name. ------------------------------------------ 11.93 05.04.2010-------------------------------------------- Fixed ZOOM into result window crashes after the 5th repeat. ------------------------------------------ 11.92 28.04.2010-------------------------------------------- New Rename DATaRec4API.dll to ch10.dll to avoid side effects when updating EdWin or EdasWin. Fixed Newest DATaRec4API.dll doesn't read "chapter 10" files. ------------------------------------------ 11.91 19.04.2010-------------------------------------------- New Very seldom all channels will displaed black. (Since Version 11.90) ------------------------------------------ 11.90 14.04.2010-------------------------------------------- New Now 16 channels are displayable with different colors instead 8 channels. ------------------------------------------ 11.89 13.04.2010-------------------------------------------- Fixed Frequency response function in very old EdasWin documenten is not upward compatible ------------------------------------------ 11.88 30.03.2010-------------------------------------------- New Video control bar is dockable in the main window. Fixed Sometimes a pretriggered video sequence shows a window without contents (black) ------------------------------------------ 11.87 19.03.2010-------------------------------------------- Fixed ASCI import with skipping of lines can show wrong first values. ------------------------------------------ 11.86 16.03.2010-------------------------------------------- Neu Enter a second path for the temporary stack. Selection is based on availability. ------------------------------------------ 11.85 10.03.2010-------------------------------------------- New Extension for GPS data measured with EdWin/EWinView ------------------------------------------ 11.84 09.03.2010-------------------------------------------- New Expansion of the possible number of different switching events for the switching force evaluation of Double Clutch Transmission ------------------------------------------ 11.83 04.03.2010-------------------------------------------- Fixed Loading a document (*. EWD file) with embedded data and a subsequent change of the data file can delete it. ------------------------------------------ 11.82 01.03.2010-------------------------------------------- Fixed Calculation with marks in modified mode shows error message 'To few operators'. ------------------------------------------ 11.81 24.02.2010-------------------------------------------- New EdasWin reads video streams which were sampled with pretrigger. ------------------------------------------ 11.80 09.02.2010-------------------------------------------- Fixed Read of RPC data files givevs an abnormal termination since version 11.78 if reportview is selectes to show the channel data. ------------------------------------------ 11.79 08.02.2010-------------------------------------------- Fixed Return from Modify mode without a channel gives an abnormal termination. ------------------------------------------ 11.78 01.12.2010-------------------------------------------- Neu Report view shows data type of channel in data file. ------------------------------------------ 11.77 26.01.2010-------------------------------------------- New Export in EdasWin format can now export the marked ranges. The sequence of marks defines the sequence of exported blocks. ------------------------------------------ 11.76 21.01.2010-------------------------------------------- Fixed Depending on the number of available data points and the previous frequency analysis set number of FFT points the number of intervals is 0. ------------------------------------------ 11.75 19.01.2010-------------------------------------------- Fixed Advanded analysis (yelliow background) shows sometimes a wrong name of channel if you append channels. ------------------------------------------ 11.74 08.12.2009-------------------------------------------- Fixed Basic aritjmetic operatinos in advanced analysis with two marks schows wrong result. This kind of operation is useful only for testing purposes. ------------------------------------------ 11.73 02.12.2009-------------------------------------------- Fixed File name will be display with missinig characters ------------------------------------------ 11.72 18.11.2009-------------------------------------------- Fixed The phase result of transfer function frf() is always in rad, too if degree is selected. eingestell immer in rad aus. ------------------------------------------ 11.71 17.11.2009-------------------------------------------- Fixed EdasWin allows licence transfer from dongle to computer, too if only a EdWin/EWinView dongle is plugged ans reports the transfer as successful. Fixed Repairkey doesn't function since version 11.70 ------------------------------------------ 11.70 16.11.2009-------------------------------------------- Fixed Some problems with dongle transfer (to computer and back) if timzone will be changed. Too with change between summertime and wintertime. ------------------------------------------ 11.68 04.11.2009-------------------------------------------- Neu Universal File Format UFF58 export and UFF58 binary export and direct reader. ------------------------------------------ 11.67 16.10.2009-------------------------------------------- Fixiert Transfer function, Auto spectrum, Cross spectrum and Coherenc don't set the selection frame automatic with the first call. ------------------------------------------ 11.66 21.09.2009-------------------------------------------- Fixed Mmax() und Mmin() calculation with selection frame generates error message "out of memory". ------------------------------------------ 11.65 18.09.2009-------------------------------------------- New Some Errors with ch10 files. -------------------------------------------11.63 25.08.2009-------------------------------------------- New Error message if the path for temporary data is not writable or invalid. -------------------------------------------11.62 24.08.2009-------------------------------------------- New Double conversion on analysis calculator (conv...) to increase resolution on following operations. Fixed ASCII Import goes wrong if line begind with column seperator. -------------------------------------------11.61 13.08.2009-------------------------------------------- Fixed $FileName in table will not be replaces correctly. New Increase the resolution by a factor of 2 when print in jpg or bmp image. Fixed Deleting a file in the file selection window can crash if a table function uses a subsequent file. -------------------------------------------11.60 31.07.2009-------------------------------------------- Fixed Folder with '.' in name gives wrong extensions and destination folders for export. -------------------------------------------11.60 31.07.2009-------------------------------------------- Neu Wave form converter wcnv(..) function on analysis calculator. -------------------------------------------11.59 03.07.2009-------------------------------------------- New Modulo function on analysis calculator. -------------------------------------------11.58 21.06.2009-------------------------------------------- New Read of DataRec4 ch10 daten files. -------------------------------------------11.57 10.06.2009-------------------------------------------- Fixed MATLAB Export is errornous for double format. -------------------------------------------11.56 27.05.2009-------------------------------------------- New Changed legend for gear force diagrams. -------------------------------------------11.55 20.05.2009-------------------------------------------- New Demo mode via internet. -------------------------------------------11.54 2.05.2009--------------------------------------------- New Gear force analysisLevel for point cloud calculation can be changed. -------------------------------------------11.53 14.05.2009--------------------------------------------- New Temperature for gear force analysis will be determinated from EdasWin. -------------------------------------------11.52 21.04.2009--------------------------------------------- Fixed time range marks will not be stored -------------------------------------------11.51 01.04.2009--------------------------------------------- Fixed Measurement data files > 4 GByte Export in block format stops at 4GB. -------------------------------------------11.5 26.03.2009--------------------------------------------- New Measurement data files > 4 GByte will be supported. -------------------------------------------11.41 20.02.2009--------------------------------------------- Fixed Autospectrum without marking the time signal may abort EdasWin. -------------------------------------------11.40 16.02.2009--------------------------------------------- New Coherence function -------------------------------------------11.39 09.02.2009--------------------------------------------- New Cross spectrum CSD New Auto spectrum PSD New Extension of transfer function with h0,h1 or h2 -------------------------------------------11.38 04.01.2009--------------------------------------------- Fixed Expansion for XSheet diagram 1 -------------------------------------------11.37 29.01.2009--------------------------------------------- New Getxaty(...) function New The parameters for ASCII Import can be saved and reloaded. New Expansion of max. evaluable channels to 2048 -------------------------------------------11.36 21.01.2009--------------------------------------------- New Higher picture resolution for color videos with new debayering algorithm. -------------------------------------------11.35 12.01.2009--------------------------------------------- New Extended dataheader for video synchronisation. -------------------------------------------11.34 10.12.2008--------------------------------------------- Fixed SKA cold switch diagram shows to many bars if change gear until 6ed gear. Fixed XSheet diagrams will not be refreshed after changing the data name in channel context menu Fixed Multiselction with printing doesn't function. (see channel selection context menu). -------------------------------------------11.33 27.11.2008--------------------------------------------- New SKA Diagrams extension -------------------------------------------11.32 11.11.2008--------------------------------------------- New Selection mode (Sln,log chan oder name) in channel selection window will be determined from the last analysis line, if not defined in file (files before 11.31) -------------------------------------------11.31 7.11.2008--------------------------------------------- New You can enter ranges for the order in order analysis Fixed New channel in analysis window resets max. disp. channels to 2. New The column Sln,Name or LChan in report view will be green colored, depending from the selection mode. -------------------------------------------11.30 5.11.2008---------------------------------------------- Fixed Absolute time axis in cursier window shows only date and hours (field is to small) -------------------------------------------11.29-------------------------------------------------------- Fixed SKA analysis with point diagram can abort EdasWin -------------------------------------------11.28-------------------------------------------------------- New rsp dataset wirth DATA_TYPE or FILE_TAPE on the wrong position is readable -------------------------------------------11.27-------------------------------------------------------- Fixed Merging of very many Files doesn't run. (File name buffer is to small) -------------------------------------------11.26-------------------------------------------------------- Fixed Export to Data Chaeck Table aborts EdasWin. -------------------------------------------11.25-------------------------------------------------------- Fixed Measurementlimit (dotted line) will not be shown correct, if the dataset is exported. -------------------------------------------11.24-------------------------------------------------------- New Data Check tests weather there is a valid sensor location no. -------------------------------------------11.23-------------------------------------------------------- Fixed Levelcrossing with channels of different sample rates will not be allowed -------------------------------------------11.22-------------------------------------------------------- Fixed Lvelcrossing properties dialog don't allow user input for ligh and low if logarithmik axis is choosed -------------------------------------------11.21-------------------------------------------------------- New Channel report view shows CAN identifier, start bit and word length. Fixed Open Data Dialog shifts the dialog everytime he i called. Fixed Cut function is enabled if selctions frame and cursor is on. New New chanel or "Dupl" function i analysis window scrolls to the end in this window. Fixed Abort if the copy function copies over the end of channel. -------------------------------------------11.20-------------------------------------------------------- New Analysis in result window, doesn't set selection frame in the parent analysis. -------------------------------------------11.19-------------------------------------------------------- New Alt+left click on channel in report view, shows this channel as first channel in the analysis view. -------------------------------------------11.18-------------------------------------------------------- New Classifying more than one signale without defining ranges classifys with range of first channel (since 11.13) -------------------------------------------11.17-------------------------------------------------------- New Erweiterung für Schalkraftauswertung Doppelkupplungsgetriebe -------------------------------------------11.16-------------------------------------------------------- New In channel selection- or channel selection report window the grouping mode doesn't function properly with marked channels and key. -------------------------------------------11.15-------------------------------------------------------- Fixed Reference in advanced analysiscan trigger abnormal program termination (look 11.13) Fixed Classifying in second analysis classifies from 0 to 0 (since version 11.14) -------------------------------------------11.14-------------------------------------------------------- Fixed Wrong channel name in analysis window -------------------------------------------11.13-------------------------------------------------------- Fixed Advanced analysis can't be edited. -> Abnornmal program termination -------------------------------------------11.12--------------------------------------------------------- New ASCII Import gives error message if "name line no." less than "unit line no." in manual mode -------------------------------------------11.11--------------------------------------------------------- New Version tracking in English -------------------------------------------11.10---------------------------------------------------- New Drag&Drop of data files from the explorer to the channel select window. -------------------------------------------11.09-------------------------------------------------------- New Add "DATA_TYPE" Keyword to RPC3 Export. Fixed Autoanalysis don't replace in RangePairR(...) function the test way length and the extapolated test way length -------------------------------------------11.07------------------------------------------------------- New The output pathes for JPEG pictures and EWD files in the Auto analysis will be checked for validity New RPC3-reader recognizes keyword "DATA_TYPE" in file header.